Presentation is loading. Please wait.

Presentation is loading. Please wait.

长飞光纤光缆(上海)有限公司 产品工程师资格认证培训 (光纤光缆及其敷设技术) 2005.10.

Similar presentations


Presentation on theme: "长飞光纤光缆(上海)有限公司 产品工程师资格认证培训 (光纤光缆及其敷设技术) 2005.10."— Presentation transcript:

1 长飞光纤光缆(上海)有限公司 产品工程师资格认证培训 (光纤光缆及其敷设技术)

2 长飞光纤系列产品 凹陷包层单模光纤G652A 匹配包层单模光纤G652B\C\D 色散位移单模光纤G653 保实单模光纤G655
50/125um多模光纤 62.5/125um多模光纤 各种特种光纤(如:100/140光纤)

3 各种单模光纤的衰减和色散

4 Loss Too High - Micro/Macrobending Loss Too High Not Single-mode
Low Water Peak Fiber 低水峰光纤 0.1 0.2 0.3 0.4 0.5 0.6 possible future window 1310 nm window Loss Too High - Micro/Macrobending C L Attenuation (dB/km) Loss Too High Not Single-mode 1200 1300 1400 1500 1600 1700 Wavelength (nm)

5 凹陷包层单模光纤 色散位移单模光纤 非零色散位移单模光纤
Dispersion-Unshifted Designs Matched Clad G.652 匹配包层单模光纤 – .09% n3 n1 Depressed Clad 凹陷包层单模光纤 8.3 mm 0.30% 46 mm n1 8.3 mm 0.34% n2 silica Dispersion-Shifted and Nonzero-Dispersion Designs n1 silica, n2 6 mm 0.75% Pedestal G.653 色散位移单模光纤 n1 0.90 % 8 mm Ring G.655 非零色散位移单模光纤

6 单模光纤的选用原则 工作波长: G652光纤工作在1550nm窗口衰减小,且具有EDFA供选用,但其在1550nm窗口色散大,不利于高速系统的长距离的传输。 G653光纤工作在1550nm窗口色散为零,但其在波分复用时会出理四波混频效应,故其被限用于单信道高速系统。 G655光纤工作在1550nm窗口衰减小、色散低,大大减小四波混频效应,故其可用于远距离、波分复用、高速系统。

7 长飞多模光纤系列产品 The 62.5/125 um multimode optical fiber, is a graded-index multimode optical fiber with a 62.5 um core diameter and a 125 um cladding diameter. It is optimized for operating window at 850 nm and/or 1300 nm with high bandwidth and low attenuation. The optical fiber is widely used in local area networks (LAN), video, data and /or voice transmission using laser or light emitting diodes at 850 nm or 1300 nm. It is specially suitable for use in Gb/s Ethernet (IEEE802.3z). Because of the features of the PCVD manufacturing process with precise controlling the refractive index profile of the fiber and the good repeatability, it offers the highest bandwidth and shows excellent attenuation performance in the market. The fiber can perform perfectly in a wide range of cable structures including ribbon, stranded loose tube, slotted core, unitube and tight-buffer cables, and is compatible in applications with optical fiber manufactured by other processes. The optical fiber complies with or exceeds the IEC type A1b optical fiber specifications. The optical fiber is also coated with a double layer UV curable acrylate.

8 差分模时延 Det. output Delayed modes Time 在有些多模光纤与激光器结合使用时,会出现差分模时延问题
差分模时延(DMD)是区分普通多模光纤和千兆/万兆多模光纤的最重要的指标! Det. output Time Delayed modes The output pulse may contain of fast and slow modes, due to some amount of profile distorsion in the centre part of the core. In an underfilled condition these fast / slow modes may contain a considerable portion of the launched power. The visible plateauing scales linearly with the fibre length. In an overfilled situation (LED) this effect has never been observed, because the power is carried by a much larger number of modes which are better compensated to arrive in time.

9 PCVD 工艺使长飞高贝光纤质量有显著优势
精确的折射率剖面控制 消除中心凹陷 消除芯层/包层界面缺陷 和普通多模光纤完全兼容 改善DMD特性 几何及光学结构完全同等于普通多模光纤 The features of these Hiband fibres are: tekst

10 HiBand 光纤千兆以太网传输距离 同行业中可传千兆以太网距离最长的光纤
For Hiband fibres the following distances are guaranteed, which are the longest reported in the industry. 高贝光纤没有采用带宽而是用在千兆以太网中的传输距离来描述光纤性能,这是因为传统的带宽不能完全描述光纤在使用激光器时的性能。高贝光纤是现在商用多模光纤中传输距离最长的品种。

11 MaxBand 光纤万兆以太网传输距离 10GBASE-SX: 300 metres 150 metres
超贝 超贝150 10GBASE-SX: metres 150 metres EMBW 850 nm: MHz.km 950 MHz.km (有效模带宽) OFLBW 850nm: MHz.km 700 MHz.km (满注入带宽) OFLBW1300 nm: MHz.km 500 MHz.km 已经推出了超贝550光纤, 万兆的传输距离保证在550米以上!

12 高贝/超贝光纤在大楼布线中的应用

13 若LAN采用单模光纤传输速率10Gb/s 成本很高 单模光纤 - 收发器(激光器,探测器)昂贵 - 连接器耦合精度高(+/-1微米)
Detector Laser 成本很高 - 收发器(激光器,探测器)昂贵 - 连接器耦合精度高(+/-1微米) - 封装成本高

14 若采用10G多模光纤工作在850nm 优点: 10G多模光纤 系统成本低(光源,接受器,封装,安装等成本均低于其他传输媒质)
Detector Laser 优点: 系统成本低(光源,接受器,封装,安装等成本均低于其他传输媒质) 安装简单,容易操作(同传统多模光纤的安装) 传输容量大(限模传输增加了通信带宽) 便于现有LAN升级

15 不同多模光纤产品的传输距离 备注:*为长飞高贝光纤产品的传输距离数据

16 光纤种类及代号 标准50 m 多模光纤(A1) 标准62.5 m 多模光纤(A1b) 标准单模光纤,也就是G652光纤(B1)
高贝50/125µm多模光纤(H) 超高贝50/125µm多模光纤(M)

17 用事实说话 ——长飞光纤与进口光纤的比较 page 2 YOFC MD

18 长飞G.652光纤 vs. 康宁SMF-28 page 2 YOFC MD

19 长飞G.652光纤 vs. 康宁SMF-28 光纤衰减:相当 偏振模色散:长飞光纤略优 芯/包同心度:平均值长飞光纤略优
包层直径:离散程度进口光纤优 模场直径:离散程度长飞光纤优 page 2 YOFC MD

20 大保实® G.655光纤 vs. 康宁Leaf光纤 page 2 YOFC MD

21 大保实® G.655光纤 vs. 康宁Leaf光纤 光纤衰减:相当 模场直径:离散程度进口光纤优 偏振模色散:本地光纤略优
色散:本地光纤更为平坦 芯/包同心度:平均值本地光纤略优 page 2 YOFC MD

22 结 论 长飞光纤质量特性总体水平与康宁光纤相当 长飞光纤与康宁光纤衰减水平相当
结 论 长飞光纤质量特性总体水平与康宁光纤相当 长飞光纤与康宁光纤衰减水平相当 长飞光纤在偏振模色散、模场直径、芯/包层同芯度、色散等质量特性和控制上略优于康宁光纤 康宁光纤在包层直径离散控制方面略优于长飞光纤 page 2 YOFC MD

23 长飞上海室内光缆生产技术 参照YDT1258.1/2/3-2003 YDT 室内光缆系列标准

24 Developing Solutions for Premises Optical Fiber Networks
Backbone Entrance Campus Backbone To the Desktop Riser Administration Horizontal Administration Jumper Cordage for Premises Administration

25 室内光缆的主要特点及用途 1、直径小,操作和布线方便 2、便于分支 3、具有适当的阻燃性 4、大多采用紧套结构而不填充油膏
5、大多采用非金属加强元件 6、单模光纤与多模光纤并用 用途 1、数据通信传输 2、光连接器跳线和尾纤的制作 3、综合布线

26 光缆型号表述方式(国标) G J F J B V-X Xn 光纤类型 光纤芯数 聚氯乙烯 (PVC)护套 扁平结构
非金属加强材料 J表示紧套被覆, D表示光纤带 扁平结构 聚氯乙烯 (PVC)护套 光纤芯数 G J F J B V-X Xn 光纤类型 室内光缆

27 长飞室内光缆型号:123-4-56-78 光缆外护套颜色:多模桔色,单模黄色 123:分类 4:细分小类 5:材料 6:光缆颜色
7:光纤数量 8:光纤类型 光缆外护套颜色:多模桔色,单模黄色

28 长飞上海室内光缆系列 Simplex Cables(单芯紧套光缆) Duplex Flat cable(双芯扁平紧套光缆)
Zip-cord Cable(8字形紧套光缆) Multi Purpose Tight Buffered Cables (多用途分支紧套光缆) Break-out Cables(多用途紧套缓冲光缆) Access building cables( 接入用光缆) Ribbon cordage(光纤带室内缆) Mobile cable(移动用光缆)

29 2、简称TBF:根据尺寸分:常用紧套光纤有600µm和900 µm二种直
一、紧套光纤系列 1、结构 2、简称TBF:根据尺寸分:常用紧套光纤有600µm和900 µm二种直 径缓冲材料不同: 1)PVC紧套光纤 2)Hytral紧套光纤 3)LSZH 紧套光纤 4)弹性聚脂体紧套光纤。 光纤纤芯 紧套缓冲层 光纤涂覆层 光纤包层

30 二、单芯紧套光缆系列 1、结构ø 1.6 mm、ø 2.0mm、ø 2.8 mm
2、型号及分类:SXC-I-VY-1B1、SXC-II-VY-1B1 SXC-III-VY-1B1、GJFJV-1Xn( 国标) 3、用途:可用于跳线缆和尾纤、PVC产品通过UL认证、 LSZH产品满足IEC and IEC C 。 PVC护套 900μ m紧套光纤 芳纶丝

31 三、双芯扁平紧套光缆 Duplex Flat Cables 型号分类:DFC-(Ø1.6mm)/DFC-Ⅱ(Ø2.0mm)/DFC-III
(Ø3.0mm)GJFBV(国标) Duplex Flat Cables Rip-cord LSZH or PVC jacket Sub unit

32 四、8字形紧套光缆 (Zip-cord cable /ZCC)
LSZH或PVC护套 芳纶 900μm紧套光纤 To be used with small form factor connectors (MT-RJ, LC e.t.c.) Space saving. Low tensile strength. To be used as interconnect cables or as horizontal cables. Relevant properties as two single fibre cables. 2x2.8mm 900 m tight buffer (alternative 600 m). One blue fibre, one natural fibre. 2x1.6mm or 2x2.0mm 900 m tight buffer (alternative 600 m). One blue fibre, one natural fibre.

33 五、多用途紧套缓冲光缆系列-I (2-12芯) 2、型号及分类: 1、结构
MPC-VY-4B1、MPC-VO-6A1b、GJFJV-10Xn、GJFJV(国标) 3、用途:As backbone in LAN’s、For premises wiring、Indoor and outdoor in ducts、Internal wiring

34 用途:Cable between patch panel and first outside joint
五、多用途紧套缓冲光缆系列-II(24-108芯) 用途:Cable between patch panel and first outside joint Large Premises networks

35 六、多用途分支紧套光缆—I(2-12芯) 型号及分类 BOC-III-VY-4B1 BOC-II-VO-6A1b GJFJV(国标)

36 六、多用途分支紧套光缆—II(12-18芯)

37 七、Access Building cable (接入用光缆)
Indoor/outdoor cable. with LSZH sheath Almost as good as stranded cables. Small dimensions Extended temperature range. Robust and compact Waterblocked to IEC F5B A degree of rodent protection. It can be buried directly in the ground and fulfils IEC LSZH out jacket Aramid yarn or Glass yarn Loose tube Fibers Fiber filling

38 七、Access Building cable (接入用光缆)
ABC- I(S)(玻璃纤维加强) 对应国标:GJGXY ABC – II(S)(芳纶加强) 对应国标:GJAXY 说明:ABC是Access Building Cable的缩写.

39 1、结构 八、扁平型光纤带室内光缆系列 RI B B O N C A B L E 2、型号表示 RBC-VY-12B1 GJFDJV(国标)
PVC护套 芳纶丝 光纤带 光纤 2、型号表示 RBC-VY-12B1 GJFDJV(国标)

40 九、移动光缆 MOBILE CABLE 缆芯由若干900um紧套光纤组成,外面缠绕芳纶纱后,挤制黑色PUR护套 Out jacket
Aramid yarn 0.9mm tight buffer fiber

41 产产品特点        非常高的抗拉强度,坚固,抗撕裂         良好的柔软性,尤其是低温柔软性         直径小,外径约6mm        良好的抗微生物和抗水解能力 阻燃(满足IEC60332-1标准)    抗纽结,当光缆打成直径为 70mm的圈时,不会形成纽结 产产品应用    军队和野外作战网络、石油探查、连接移动器材(如:电视转播、救援临时通信、大型龙门吊装设备等)、  可提供2~6芯单、多模光缆  实地测试 三种路面情况:软土壤、硬土壤和混凝土上,被三种车辆碾过;每种车辆和路面的组合情况下,光缆被碾过25次,最大衰减变化为0.5dB;当车辆停在光缆上时,没有衰减变化。

42 长飞上海室外光缆生产技术 参照YDT 核心网用光缆

43 影响光纤性能和寿命的因素 应 力 潮 气 氢 气

44 应 力 光纤具有很高的强度——如果没有表面缺陷 不可避免的随机的裂缝——表面缺陷 在应力作用下,裂缝逐渐扩展——光纤断裂
应 力 光纤具有很高的强度——如果没有表面缺陷 不可避免的随机的裂缝——表面缺陷 在应力作用下,裂缝逐渐扩展——光纤断裂 光纤筛选——光纤获得保证强度 侧应力产生微弯损耗——衰耗增加

45 在应力作用下,潮气的存在会加速光表面裂缝的扩展,使光纤更易于断裂。
潮 气 在应力作用下,潮气的存在会加速光表面裂缝的扩展,使光纤更易于断裂。

46 氢 气

47 光缆设计的基本原则 针对光纤的弱点,光缆设计应遵循以下原则: 为光纤提供机械保护,使光纤在各种环境下免受应力 必须防止水分和潮气侵入
必须避免光缆中产生氢气,尤其避免形成氢压

48 光缆设计——机械保护 加强芯——主要抗拉元件 松套管——将光纤外界隔绝,提供最基本的保护 余长控制——二套及成缆
金属带纵包——防潮、防水、抗侧压、抗冲击 护套——抗侧压、抗冲击、抗弯曲

49 光缆设计——防潮 径向防水——纤膏及缆膏填充 ——金属带纵包 ——PE护套 轴向防水——纤膏及缆膏填充 ——阻水环、阻水带、阻水纱
——单根加强芯

50 光缆设计——避免形成氢压 氢气源于光缆材料 严格挑选材料,控制材料析氢量,控制不同 材料间的反应析氢 特别是金属件的析氢控制

51

52 光缆生产的工艺流程 光纤着色 护层 二次套塑 测试及包装 成缆 每道工序都进行检测,严格控制产品质量。

53 光纤着色 将光纤着上鲜明、光滑、稳定可靠的各种颜色,以便于在光缆生产和使用中易于辨认光纤 在着色的整个过程中要避免对光纤的任何损伤和危害

54 二次套塑 给光纤套上一个合适的与光纤长度相等的松套管 在管与光纤之间填充稳定的触变型材料 给予光纤最基本和关键的保护

55 成缆工艺 将多根松套管或填充绳按一定的绞合节距绞合在加强芯周围,并填充缆膏 增加光缆的可弯曲度 提高光缆的抗拉能力,改善光缆的温度特性

56 护层工艺 按照光缆的使用环境,在缆芯外加上不同的保护层,以便对光纤进行更好的保护,包括金属带(钢带、铝带)纵包.

57 长飞(上海)松套层绞光缆主要特性

58 长飞(上海)松套层绞光缆的优良性能来自于:
最佳的余长控制 最佳的绞合节距 结构的整体性

59 长飞(上海)松套层绞式光缆 良好的结构设计 专业的工艺控制 严格的材料选取 在保持优良性能的同时, 直径比其它厂家的同类光缆细1-2毫米,
重量轻20%以上。

60 松套层绞光缆种类 管道缆/架空缆GYTA结构 直埋缆GYTY53、GYTA53、GYFTY53、GYFTA53结构 架空缆GYTS结构
无金属光缆(GYFTY、GYHTY) 其它特种光缆:阻燃缆、尼龙缆、 钢丝铠装缆等

61 管道光缆(GYTA) PE sheath 聚乙烯 APL 涂塑铝带 Loose tube 松套管 Tube filling 松套管填充物
Fiber 光纤 Cable filling 缆芯填充物 Strength member 涂塑钢丝

62 架空光缆(GYTS) Fibre 光纤 PE sheath 聚乙烯 Tube filling 松套管填充物
Loose tube 松套管 Tube filling 松套管填充物 Fibre 光纤 Cable filling 缆芯填充物 Water blocking material 阻水材料 PSP 涂塑钢带 Filler 填充绳 Strength member 加强芯

63 直埋光缆(GYTY53、GYTA53)

64 中心束管光缆(GYXY、GYXTW)

65 ADSS光缆结构

66 ADSS光缆的关键性能参数 外径和重量 影响光缆所受的风荷、冰荷,以及与安装金具的配套 最大允许工作张力
决定光缆适用的最大档距(与气象条件相关) 光缆外护套类型 不同种类的护套决定光缆的耐电蚀性能

67 ADSS光缆适用范围 ADSS光缆一般架设在现有高压、超高压线路上,如城网改造、农网改造等
其中,线路电压超过110kV 时,ADSS光缆采用耐电痕外护套; 线路电压不大于110kV 时,ADSS光缆采用聚乙烯外护套

68 特殊光缆(水缆) PE outer sheath 聚乙烯外护 GYTA53缆芯 steel wire 钢丝

69 特殊缆:防鼠防蚁光缆 目前,光缆行业采取了三种防鼠方式 : 1、药物防鼠(在护套料中加入添加剂) 2、屏障防鼠(如双钢带铠装、钢丝铠装)
3、刺激物防鼠(如玻璃纤维)

70 JETnet Cable(气吹光缆)

71 JETnet 是一种完整的电信网络解决方案,适用于室外光缆网络的各个部分,其基础是将成束的微型子管布放到直埋的高密度聚乙烯(HDPE)母管中。
在长途网中,将所需芯数(或高芯数)的光缆布放到各个子管中,保证光纤数量可随业务量的增长而增长。 在接入网中,先将子管进行简单的耦合,再根据客户的要求将具有室外缆性能的微缆气吹入子管,这样不需接续就可完成分歧。按这种方法,接入网的容量将随需求增长而扩大。

72 子管束气吹距离可以超过2km; 微缆气吹距离可以达到6km; 施工只需2-3人,人均每人每天可以步放1km光缆。

73 光纤组装密度高,利用子管可充分利用管孔资源 初期投资低, 投资随市场需求增长逐步增加 无须预先决定接头盒位置
JETnet® 的全面解决方案 为长途和接入网提供解决方案 光纤组装密度高,利用子管可充分利用管孔资源 初期投资低, 投资随市场需求增长逐步增加 平行和纵向扩容能力强 无须预先决定接头盒位置 低成本的Y型连接器 随时随地实现分歧 功能强大的室外技术

74 光缆的优劣判断 光缆的设计: A、余长(二套及成缆) B、机械强度不够 C、阻水不满足要求(3米光缆,1米水柱,24小时) D、光缆结构材料
光缆使用的材料:使用不合格的材料 回收PE 芳纶达不到拉力要求 着色油墨等等

75 美国UL认证 广电入网证 中石油天然气管供应商资质认证
长飞上海公司及其产品通过的国内与国际认证 ISO9001&TL9000 ISO14001 泰尔认证 欧洲RoHS认证 美国UL认证 广电入网证 中石油天然气管供应商资质认证

76 长飞上海光缆的使用说明

77 光缆的使用说明 光缆的选择使用 请用户在选择使用光缆时应依据有通信线路工程专业设计资质的单位意见和/或建议。光缆的敷设、连接、安装和维护应由专业人员或在专业人员指导下进行。 光缆的选择使用应根据光缆线路传输速度和容量、传输距离、传输设备的要求等因素选择光缆中光纤的类型和数量,应根据光纤通信工程的环境条件如是否适合架空、管道、直埋、浅水下敷等以及气候条件、敷设环境的特殊要求等选择光缆的型式。

78 产品接收 一般收货人应在收到货物的十天内对产品进行测试验证,以防运输途中的损坏。

79 运输和贮存 光缆盘应竖立放置,请勿平放,也不得堆放。 盘装光缆应按缆盘标明的旋转箭头方向在平整地面上滚动,但不得作长距离滚动。
盘装光缆应防止冲撞、挤压和任何机械损伤。 盘装光缆应避免雨淋、受潮或长时间爆晒。 光缆贮运温度应控制在-40℃~+60℃范围内,如果超出这个温度范围,安装敷设前应进行复验 安装敷设时的环境温度应不低于-15℃。

80 敷 设 请用手撬杆撬启封板,并注意防止封板上的钉子扎伤光缆或人员!
拆开封板后,请将拆下的封板远离光缆放置,并将钉子取出或弯折,以避免伤害人员! 将粘贴于包裹的塑料膜外端的封胶带揭下,沿塑料膜缠绕相反的方向卷绕取下塑料膜,露出光缆。 注意:不要直接拉着塑料膜拖拽光缆盘,也不得用刀具或其它利器割划塑料膜,否则会损坏光缆! 光缆在施工中所受到的拉伸力和压扁力不得超过表1中规定的允许短暂力,运行使用时不得超过表1中规定的长期力。(合同有规定的除外)

81

82 光缆允许的最小弯曲半径应符合表2的要求

83 将光缆从光缆盘上绕出时,应使用机械装置支撑穿过光缆盘中心孔的轴棒,采用机械方式或人力转动光缆盘,将光缆从光缆盘上平缓放出。只牵引光缆端头而不主动转动光缆盘会导致布放张力失控容易造成光缆承受张力过大,导致光缆损坏,在遇到转弯处还会造成光缆受到较大的侧压力,挤压套管、损伤光纤。 光缆应平缓地放出,光缆盘旋转速度不要过快,否则会导致光缆内端松弛,从而导致光缆“垮线”。 光缆施工布放过程中,应采取退扭措施,如将光缆盘绕“∞”字,以保证光缆布放平直,禁止扭转,防止打小圈、浪涌等现象,以免损伤光缆。对于较重的光缆如水缆,应更加注意。 施工实践证明,将光缆从光缆盘上绕出时,先将光缆盘绕成“∞”字状,然后布放,这样能有效地防止“背扣”的产生,避免损伤光缆。 牵引光缆时,应有专人指挥协调,并采用包括对讲机在内的有效联络手段。牵引力应加在光缆的加强件上,而不要直接牵引护套

84 光缆敷设过程中若需弯曲光缆,例如从地面牵引上杆架、从地面牵引入人孔,应采用滑轮,其半径应符合表2中规定的要求。
光缆布放后应及时采用OTDR测试,若发现布放过程中出现的故障,应及时采取应对措施。由于OTDR测试在被测试光纤的两端附近存在盲区,如连接后的测试中才能发现。光缆端头必须做密封防潮处理,不得浸水。 在中国北方地区布放光缆,应注意避免靠近供热管线;用管道敷设光缆时,应避免管道浸水。 光缆的适用温度范围为-40℃~+60℃,如订货合同规定与本说明书不一致,以订货合同规定为准。

85 光缆连接和固定 光纤连接 光纤接续通常采用熔接法。熔接前应按规定的要求制作光纤端面,不按规定操作可能会导致接续处光纤强度下降,从而导致熔接后的光纤易于断裂。为了获得理想的接续损耗,必须保证光纤接续端面处平整、清洁。

86 光纤保护和收容 由于接续时剥离了光纤涂覆层,接续处的光纤呈裸露状态,应对光纤接头采用增强保护的方法。常用的保护方法有热可缩保护法和V型槽胶剂保护法。增强后的接头应在接头盒中加以固定。 由于连接光纤时会产生一定长度的余纤,需要将它们妥善地收容在接续盒内。常用的收容方式有用于紧套光纤的盘绕式和层叠式。光纤应整齐地盘绕,弯曲半径不得小于37.5mm,并加以固定。特别是对于盘绕光纤竖立放置的情况,应防止盘绕的光纤垮落引起光纤弯曲半径减小,致使弯曲损耗增加。

87 套管盘绕 对于层绞式光缆和中心束管式光缆,光缆连接处剥去护套后的套管应放置于接头盒内加以保护。套管的盘绕半径应能保证套管中光纤的弯曲半径大于37.5mm的要求。同时,在盘绕时应防止套管被挤压或折弯而损伤光纤或造成光纤断裂。

88 光缆的加强件应固定在接头盒内。除了采用紧固螺栓外,对于金属加强件,可以将伸出固定装置的部分折弯成“L”状,这样可以加强固定效果。
金属加强件和金属护层在接续出的电气连接,如在绝缘连接、电器导通方面,不同的线路环境会有不同的要求,施工时应按设计要求处理。

89 接头盒的密封和固定 接头盒应按规定要求密封,防止渗水或潮湿气体进入而对其内部的光纤产生损害。 光缆接头完成后,应根据不同敷设方式进行安装、固定和保护。接头处两侧的光缆应按施工规范预留足够长度的光缆并整齐盘旋固定。架空附设的光缆应在接头附近的两侧制作伸缩弯,接头盒不应悬挂于杆架之间,而应牢靠的固定于杆架上。

90 安全与环境保护 警告:任何时候不要将光缆中的光纤对着人的眼睛,以防止从光纤中射出的光包括肉眼看不见的光灼伤眼睛。
进行光缆连接时,应小心不要被光纤扎伤。如果被光纤扎伤,务必尽快到医院就诊。 请将光缆包装材料、光缆敷设过程中产生的废弃光缆段或光缆元件以及废弃不用的光缆收集分类,送废物处理机构处理,禁止自行焚烧,以免污染环境。

91 常见故障现象和解决方案

92

93 谢谢大家!


Download ppt "长飞光纤光缆(上海)有限公司 产品工程师资格认证培训 (光纤光缆及其敷设技术) 2005.10."

Similar presentations


Ads by Google