Presentation is loading. Please wait.

Presentation is loading. Please wait.

VAC电流传感器用于工业电源 VAC Current Sensors for Industrial Applications

Similar presentations


Presentation on theme: "VAC电流传感器用于工业电源 VAC Current Sensors for Industrial Applications"— Presentation transcript:

1 VAC电流传感器用于工业电源 VAC Current Sensors for Industrial Applications

2 应用领域 Applications 变频器 (FREQUENCY INVERTERS) 不间断电源 (UPS) 交流转换器-太阳能电池
( AC CONVERTER - SOLAR CELLS ) 电池充电器,交流转换器-升降设备… (BATTERY CHARGER, AC CONVERTER -FORK-LIFTS, ...) 电池充电器,辅助转换器-牵引设备… (BATTERY CHARGER,AUXILARY CONVERTERS- TRACTION, ...) 焊机 (WELDING MACHINES) 开关电源(SWITCHED MODE POWER SUPPLIES) 其他 (others)

3 磁电流传感器的主要制造厂家 Main manufacturer of Magnetic Current Sensor
Magnetic Sensor using the induced magnetic field in the magnetic core Closed Loop In = 1 … 700 A Imax = 1250 A f = DC … 100 kHz Tu = -40 … 105 °C UB = / V VAC, LEM, ABB, Honeywell Open Loop Closed Loop with Hall-element with Hall-element with magnetic field probe only VAC

4 VAC 电流传感器 VAC Current Sensor
闭环磁探针式电流传感器 Closed Loop Current Sensors with VITROVAC Field Probe 低偏移电流(Low offset current) 无温度漂移(No temperature drift) 高动态范围(High dynamic range) 大电流小体积(Large current in small build size) H B The VITROVAC field probe

5 温度漂移特性曲线 Temperature Dependence of Offset Current
Comparison of current sensors with VITROVAC field probe and Hall-sensor devices I0 [A] 0,5 0,4 0,3 typical current sensor with Hall probe 0,2 various current sensors with amorphous metallic magnetic field probe 0,1 -60 -40 -20 20 40 60 80 100 120 -0,1 T [°C] -0,2

6 VAC标准系列电流传感器

7 VAC新系列高精度电流传感器 VAC new active current sensors for maximum accuracy
Closed Loop In = 6 … 200 A Imax = 300 A f = DC … 100 kHz Tu = -40 … 85 °C UB = +5V/+- 12 / V operation with the IC DRV 401

8 VITROVAC Magnetic Probe Type
总误差:The sum of all errors (accuracy精度, linearity线性度 and offset偏移) (This total value is more important than the error value only at room temperature) VAC closed loop sensors with magnetic probe: 约1%到1.5%在整个应用温度范围-40 ~85 °C! Closed loop Hall effect -sensors: 约2%到3%, 应用温度范围仅-25 ~85 °C VITROVAC Magnetic Probe Type Hall Effect Type

9 VITROVAC Magnetic Probe Type
输出信号:The output signal VAC closed loop sensors with magnetic probe: 低位高频周期性信号, 易滤除, 几乎无输出噪声! Closed loop Hall effect -sensors: 高位低频信号, 叠加多种频率噪声, 无法滤除! VITROVAC Magnetic Probe Type Hall Effect Type

10 VITROVAC Magnetic Probe Type VITROVAC Magnetic Probe Type
快速的响应和真正的过流保护: Quick response and real over current protection! VITROVAC Magnetic Probe Type VITROVAC Magnetic Probe Type Hall Effect Type

11 VAC新系列高精度电流传感器

12 VAC电流传感器用光伏逆器(PV inverter)漏电流检测
Type N = 1: Current range Supply voltage(s) Output 4645-X IN = 0,3 A, I max = + 0,85 A + 5 V Voltage 4646-X IN = 0,3 A , I max = + 0,85 A + 5 V Voltage 4646-X IN = 0,15 A , I max = + 0,27 A V Voltage operation with the IC DRV 401 DI – Sensor on Evaluation Board 

13 主要客户 SMA, Germany Kaco, Germany SIEMENS, Germay Fronius, Austria
Xantrex, USA APC, USA . 茂迪(MOTECH), TW 阳光电源(SPS), China 山特(SANTAK), TW others